A corner cabinet with a pentagon plan: two wings meet at the corner and a diagonal chamfered front carries the door. The Enclosed frame checkbox switches between the two builds - checked is the wall variant (full top panel, no Gola), unchecked is the ground variant (open top with back rails, countertop supports and Gola available).
Validation requires each wing's depth to be smaller than the other wing's width, otherwise the chamfer face collapses; the derived "Chamfer face width" readout in Dimensions shows the resulting door face width live.
Dimensions
Corner types are dimensioned per wing. With Symmetric dimensions checked (the default), the right wing mirrors the left; uncheck it to size each wing separately.
Symmetric dimensions - checkbox, default on. While checked, the right wing's width and depth mirror the left wing and their inputs are hidden.
Left Width - number, mm, default 600, min 150. Left wing width, along its wall.
Right Width - number, mm, default 600, min 150. Right wing width, along its wall. Hidden while Symmetric dimensions is checked.
Left Depth - number, mm, default 330, min 100. Left wing depth, wall to front. Must be smaller than the right wing's width.
Right Depth - number, mm, default 330, min 100. Right wing depth, wall to front. Must be smaller than the left wing's width. Hidden while Symmetric dimensions is checked.
Height - number, mm, default 700, min 100. Outer cabinet height.
Panel Thickness - number, mm, default 18, min 5, max 50. One thickness drives every carcass panel, shelf and rail. Doors have their own Door Thickness.
Chamfer face width - read-only display. Live readout of the diagonal door-face width that results from the wing dimensions. Shows a dash when the dimensions leave no valid chamfer (a wing depth must stay smaller than the opposite wing width).
Cabinet Options
Enclosed frame (no open top) - checkbox, default off. Builds a fully closed carcass instead of the open-top ground-style frame. Checked: wall variant (full top panel, no Gola). Unchecked: ground variant (open top with back rails, Gola available). This swaps the whole build, not just the top.
Support and Rails
Back Rail Depth - number, mm, default 70. How far the top back rail extends downward from the cabinet top. Hidden while Enclosed frame is checked.
Back Rail Left Width - number, mm, default 100. Width of the vertical back rail on the left back, at the wall corner.
Back Rail Right Width - number, mm, default 80. Width of the vertical back rail on the right back, at the wall corner.
Back Spacing
Back Space plus Cutting Tool Space defines the back inset: the plane where the fiber back panel sits and where shelves stop at the back.
Back Space - number, mm, default 18. Depth reserved at the back for the fiber panel: the distance from the cabinet's back edge to the fiber back panel.
Cutting Tool Space - number, mm, default 4.1. Extra CNC tool clearance added around the fiber groove.
Shelves
Shelves are spaced evenly with equal clear heights. Shelf depth is the cabinet depth minus the shelf front inset and the back inset. At least 50 mm of clear height per shelf gap is enforced; too many shelves for the height is a validation error.
Add shelves - checkbox, default on. Adds shelves; the count field appears while checked.
Number of Shelves - number, default 1, min 0, max 10. Number of shelves, spaced evenly. Shown while Add shelves is checked.
Shelf front inset - number, mm, default 0. Setback of the shelves from the carcass front edge.
Back Panel (Fiber)
The fiber back is a thin sheet seated in grooves: it is oversized by the groove depth on every captured edge and the surrounding panels get matching grooves. Its position comes from the Back Spacing section.
Add fiber back panel - checkbox, default on. Adds the thin fiber back panel. The fields below appear while checked.
Fiber Thickness - number, mm, default 4.1, min 1. Thickness of the fiber sheet, and the width of the grooves that hold it. Shown while Add fiber back panel is checked.
Fiber Extension (Groove) - number, mm, default 10, min 1. How far the fiber extends into the surrounding panels on each side. With grooves enabled they are cut to this same depth; without them the fiber simply stays oversized. Shown while Add fiber back panel is checked.
Fiber Top Inset - number, mm, default 20. Distance below the back rail top where the fiber panel ends, so the fiber stops under the rail on open-top cabinets. Shown while Add fiber back panel is checked. Hidden while Enclosed frame is checked.
Fiber Corner Inset - number, mm, default 20. Inset from the corner's vertical back rail where each wing's fiber panel ends. Shown while Add fiber back panel is checked.
Doors
Doors sit side by side. Door height is the cabinet height minus the top and bottom spacing; door width divides the cabinet width minus all left/right spacings by the door count. "Right" spacing is the viewer's right when facing the cabinet. When Gola is enabled, the Gola gap is added to the door top spacing.
Add doors - checkbox, default on. Adds the doors; the fields below appear while checked.
Number of Doors - number, default 1, min 1, max 6. Number of side-by-side doors. Shown while Add doors is checked.
Door Thickness - number, mm, default 18, min 5. Door panel thickness, independent of the carcass panel thickness. Shown while Add doors is checked.
Door Spacing (Uniform / Individual) - number, mm. Reveal around the doors. Uniform applies one value to all sides; Individual (the default mode) sets Top, Bottom, Left and Right separately - defaults 0 top and bottom, 1.5 left and right. Sides are the viewer's left/right facing the cabinet. Shown while Add doors is checked.
Hinge Stock - stock picker, default Catalog hinge default. Hinge hardware from the stock catalog, placed at each door's hinge side and priced per hinge. None places no hinges. Shown while doors are enabled.
Hinges per Door - number, default 2, min 0, max 6. Hinges placed per door. Shown while doors are enabled.
Glass Panel Cutout
Cuts a rectangular opening through each door, leaving a frame for a glass insert. The offsets are the distance from each door edge to the opening. Offsets are validated against the door size (twice the offset must stay under the door dimension).
Enable glass panel cutout - checkbox, default off. Cuts the glass opening in each door. Offsets appear while checked - Uniform for one value on all sides, Individual (default) for Top, Bottom, Left, Right separately; all default to 50.
Handles and Gola
Gola is an integrated finger pull - a notch cut into the side panels at the front (Cut Height down from the top, Cut Depth toward the back) plus two rails at each Gola position: a horizontal bottom rail and a vertical lip at the back of the cut. The Gola gap is the finger opening above the doors or between drawer fronts. Handles and hinges are hardware placed from the stock catalog; they carry their stock id for pricing.
Gola applies to the ground variant only - it is hidden while Enclosed frame is checked. Only the Gola profile is cut; rails extend from adjacent cabinets.
Add Gola handle - checkbox, default off. Enables the Gola profile; the fields below appear while checked.
Gola Gap - number, mm, default 30. Vertical finger-pull opening above the doors or drawer fronts - added to the door top spacing. Shown while Add Gola handle is checked.
Cut Height - number, mm, default 70. Gola cut height, measured downward from the cabinet top. Shown while Add Gola handle is checked.
Cut Depth - number, mm, default 50. Gola cut depth, from the front edge toward the back. Shown while Add Gola handle is checked.
Rail Thickness - number, mm, default 18. Thickness of the Gola rail panels. Shown while Add Gola handle is checked.
Add Handle - checkbox, default off. Places a handle bar on each door from the selected Handle Stock, priced per handle - vertical at the opening edge on hinged doors, horizontal and centered on drawer fronts. The stock picker appears while checked.
Legs
Legs are placed 50 mm in from the cabinet corners; a 5th and 6th leg go front and back center. Their length comes from the selected leg stock's catalog length - with no leg stock selected (or a stock without a length), no legs are generated. When placing the cabinet, it is lifted so the legs rest on the clicked plane.
Leg Stock - stock picker, default Catalog leg default. Leg hardware from the stock catalog; the leg length comes from the stock's catalog entry. None generates no legs.
Leg Count - number, default 4, min 0, max 6. Number of legs. Floor types default to 4; wall-hung types default to 0.
Materials, Tags and Stocks
Three assignments per part group. Material is the visual finish only - leave it as None to use the assigned Stock's catalog material. Tag sets the part's SketchUp tag (model organization and visibility). Stock selects the catalog sheet the part is cut from - it drives nesting (which sheet the panel lands on) and pricing. One Uniform/Individual toggle switches between a single Frame row for the whole carcass and one row per part group. The separate rows (Fiber, Door, and where present Gola Rail or the HDF rows) always apply regardless of the toggle.
Individual part group rows for this type: Sides, Bottom, Rails, Shelves.
Separate rows (always active): Fiber, Door, Gola Rail.